beautypg.com

Welltech SPCI2S Intel NetStructure SS7 Boards User Manual

Page 107

background image

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2

Page 107

The group id of the circuit group in the range 0 to one less than the number of groups supported.

The destination point code for the circuits in the circuit group.

The Circuit Identification Code (CIC) that will be allocated to the first circuit in the circuit group.

The logical id for the first circuit in the circuit group. It must lie in the range 0 to one less than the
number of circuits supported.

A 32 bit mask with bits set to indicate which circuits are to be allocated to the circuit group. Bit zero
must always be set as it represents the base_cic/base_cid. Subsequent bits represent the
subsequent circuits.

A 32 bit value containing run-time options for the TUP circuit group (see ‘Configure Circuit Group
Request’ section of the TUP Programmers Manual).

The instance number of the user application. Typically only a single user application exists so this
field should be set to zero.

The module_id of the user application.

Originating Point Code. The local point code for all circuits in the group.

The value to be used in the sub-service field of all TUP messages for this circuit group.

This field is reserved for future use and should be set to zero.

This field is reserved for future use and should be set to zero.

This manual is related to the following products: