beautypg.com

Digit 10 – arc detection level, Digit 11 – loops to perform, Your hal tester – Seaward ClareHAL User Manual

Page 124

background image

123

Digit 10 – Arc Detection Level

(H101, H103 H104 AC/DC Hipot &

DC IR)


Digit 10 represents a level of arcing detection, which will terminate the
current test sequence when selected level is reached.

Digit 10 : Arc Detection Level

‘0’

Disabled / Off

‘1’

Most sensitive setting – All arcs terminate

‘2’
‘3’
‘4’
‘5’ Medium

sensitivity

‘6’
‘7’
‘8’
‘9’ Least

sensitive

– Only large arcs

Digit 11 – Loops to Perform

Digit 11 represents the number of times a test or linked sequence
should be performed.

The user may use the red STOP key before or during a test and from
the ‘abort options menu’ elect to move to the next test or the next test
after a linked sequence of tests if a smaller number of loops is required.
The STOP button will also terminate an unlimited number of loop tests.

The value of ‘0’ indicates that a test is as ‘follow-on’ test and forms
part of a linked sequence. The linked sequence begins with a test
code that has a non-zero loops value and ends when there are no more
test codes or when the next test code has a non-zero loops value. A
linked sequence is performed the number of times specified by the first
test in the sequence.





Your HAL tester