Figure 46: nct set – NavCom StarUtil Rev.G User Manual
Page 53
StarUtil User Guide – Rev. G
Figure 45: Rover / Navigation & Tracking Setup Window
efer to Figure 45 for the options below:
• Unit Port Configuration Button: This button opens the Unit Port Configuration window
(see Figure 40).
• Antenna Setup Button: Click this button to set the appropriate bias adjustment values for
the antenna model in use (
na Bias window opens (see
Figure 21):
SET)
n
imeters
R
optional). The Vertical Anten
• Use Antenna Bias: Click the Yes or No button to determine if the values set in the
Vertical Antenna Bias window are applied to measurements.
• Use SET Corrections: Click the Yes or No button to determine if Solid Earth Tide (
corrections are applied to measurements.
quirements for output of SET corrections:
Re
• Message 0x49, W6 B6 set to Apply Correction
5-51
• NCT SET scheduled for output in the
NMEA
• A license for the StarFire™ subscription service.
The option, RTG input, must be set to Use on
the Rover / Tracking & Navigation Setup
window.
• Valid
Navigation
• Valid SET correctors (A minimum of 1 run of the
SET algorithm. These are an integral part of
StarFire™ corrections.)
Figure 46: NCT SET
If the criteria above are met, the receiver applies the SET corrections to the positio
solution. The B1 Solution tab displays SET North, East, and Up corrections in mill
(see Figure 44).