Ch 9 - counter/timer window, Counter/timer window 9 – Measurement Computing DaqView User Manual
Page 55

Counter/Timer
Window
9
When supported by a device, there are typically two Counter/Timer modes: Totalize Input and Square
Wave Generator Output.
DaqBoard/3000 Series and Personal Daq/3000 Series devices make use of a Counters
panel that appears in the Configure Systems Hardware Window. The panel allows for
enhanced counter configuration that is possible with those devices. See the following
page for additional information.
Totalize Input
– Counts rising or falling edges of signals from the related pin on P3 adapter. Each channel
has its own
Square Wave Generator Output
– Outputs a square wave on each of 2 channels with a selectable
frequency and duty cycle.
With most devices channels that are enabled in the scan cannot be used from the
asynchronous counter/timer window.
DaqView User’s Guide
907994