Measurement Computing DaqView User Manual
Page 21
2.
Under Digital Option Cards, select the expansion down-arrow for the chosen Daq Device
channel, for example, P2 Channel 0. A “drop-down” will list the available digital DBK
options.
TIP
: An alternative to using the expansion down-arrow to access the external connection drop-
down list, is to click within the text box. For example, in the following figure, after clicking on
P2 Channel 5’s “None,” a drop-down list will appear, like the one shown for Channel 0.
Configure System Hardware Screen Showing Digital Option Cards,
External Connection, P2 Channel Pull-down List for Channel 0
3. Select the applicable digital DBK card.
If the card has jumpers or switches, a related window will appear. Two examples follow. The first is
for DIP-switch and jumper settings for a DBK208. The other is for a DBK25 DIP-switch.
Examples from Setup Dialog Boxes (These vary according to the DBK)
4. If applicable, set the software DIP-switch and other settings (such as jumpers) to match the
hardware settings on the actual DBK(s).
5. After all the settings are confirmed correct, select OK to return to the DaqView main screen.
6. From DaqView, complete the channel setup, acquisition setup, and data destination setup for
each of the new DBKs.
This completes the software setup for digital DBK options.
DaqView & ViewXL User’s Guide
886994
Configure System Hardware 3-5