5.5.5
Tested Resolution
During internal testing, we achieved good picture quality at the following
resolutions (the values are independent of the cable and IVT settings used):
Meters Resolution
Screen Refresh Rate
100
1600 x 1200
Max. 85 Hz
150
1600 x 1200
60 Hz
200
1280 x 1024
Max. 85 Hz
300
1280 x 1024
60 Hz
This overview is not intended to represent maximum values.
5.6
Administering a Console / Establishing an
OpenAccess Console
After you select the CONSOLE submenu in the list field of the
CONFIGURATION menu, the CONSOLE CONFIG submenu opens.
C o n s o l e C o n f i g
CON 00000028
Standard
CON 00000029
Standard
CON 00000030
OpenAccess
CON 00000031
Standard
CON 000000121
Standard
CON 000000122
Video
CON 000000134
Standard
CON 000000138
Standard
F4: Delete F5 Edit
SPACE: Toggle type
F6 Enable / Disable
F2: Save
The meaning of the columns within this window is as follows:
Column 1 Name: This column displays the logical name assigned to this
physical console. In the default state, this name is the device
ID of the UCON (or UCON-s or UCON-a) connected to this
console port. This name can be edited by pressing the
F5
key on the keyboard.