beautypg.com

5 tested resolution – Guntermann & Drunck CATCenter X systems Operation User Manual

Page 89

background image

Guntermann & Drunck GmbH

CATCenter Operating Manual

Page 89

5.5.5

Tested Resolution

During internal testing, we achieved good picture quality at the following
resolutions (the values are independent of the cable and IVT settings used):

Meters Resolution

Screen Refresh Rate

100

1600 x 1200

Max. 85 Hz

150

1600 x 1200

60 Hz

200

1280 x 1024

Max. 85 Hz

300

1280 x 1024

60 Hz


This overview is not intended to represent maximum values.

5.6

Administering a Console / Establishing an
OpenAccess Console


After you select the CONSOLE submenu in the list field of the
CONFIGURATION menu, the CONSOLE CONFIG submenu opens.

C o n s o l e C o n f i g

CON 00000028

Standard

CON 00000029

Standard

CON 00000030

OpenAccess

CON 00000031

Standard

CON 000000121

Standard

CON 000000122

Video

CON 000000134

Standard

CON 000000138

Standard

F4: Delete F5 Edit

SPACE: Toggle type

F6 Enable / Disable

F2: Save


The meaning of the columns within this window is as follows:

Column 1 Name: This column displays the logical name assigned to this

physical console. In the default state, this name is the device
ID of the UCON (or UCON-s or UCON-a) connected to this
console port. This name can be edited by pressing the

F5

key on the keyboard.