Guntermann & Drunck CATCenter X systems Operation User Manual
Page 117

Guntermann & Drunck GmbH
CATCenter Operating Manual
Page 117
To assign the targets displayed in the list field to a HardBoot, use the
UP
ARROW
and/or
DOWN ARROW
keys or the mouse to move to the desired
entry and press the
F5
key. An additional menu opens.
E d i t P o w e r S e t t i n g s
C P U 0 0 0 0 0 2 0 9 C P U A c c o u n t i n g 1
L O C 0 0 0 0 1 6 6 4 S e r v e r r o o m
Hardboot
1
Port
2
Hardboot
2
Port
3
Hardboot
N o n e
Port
N o n e
ESC
F2: Save
In the second line of the header, you will find the physical ID in the left column
(as described above) and the logical name of the selected target in the right-
hand column.
The third line displays the non-editable physical name of the CATCenter in the
left column and the editable logical name in the right column (see
Chapter
5.8.8
).
All yellow entries in the list field are only editable when a HardBoot has been
recognized on the CATCenter.
In the column "HardBoot", you define to which HardBoot the selected target is
connected. The following selections are available:
None No HardBoot is connected
1 – 16 Numbering of the available HardBoots Up to 16 HardBoot
CCX can be cascaded; each one is assigned an address via a
DIP switch.
In the column "PORT", you define on which CPU-Port the selected target is
connected to the HardBoot. The following selections are available:
None No HardBoot is connected
1 – 8 CPU port numbering on the HardBoot. Therefore, the first
CPU port on the HardBoot is number 1, the second number 2,
etc.
To save the settings, exit the menu with
F2
. Use the
ESC
key to discard the
changes you have made. In both cases, you return to the POWER
MANAGEMENT submenu.