Input/output – read local – GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual
Page 30

PC Programming
PL1877A Microprocessor Radio Telephone Interconnect
12/10 24
Input/Output – Remote Programming -Dialing Directory
If there are multiple PL1877A installations, you have the option of storing up to 10 names, phone
numbers and Telephone Line Access prefixes in the Dialing Directory. These can be selected and dialed
directly from the screen entries.
To store entries in the directory, enter up to 16 digits/symbols. Valid entries are:
0-9, A-F, *, #
Standard DTMF digits
-, ()
Dash, open and close parenthesis
, (comma)
2-second pause
@
1 or more rings, then wait 5 seconds
! Flash
hook
0-9, A-D
Telephone line dialing prefix
(6-digit access code allowing remote access to PL1877A)
When Remote Programming is completed, select Program Remote and click on OK after the progress bar
reaches 100%.
N
OTE
: If the IAPS only programs a partial program (because the user canceled or it failed before the
program was completed), default parameters are reloaded.
Input/Output – Read Local
After selecting the Read ITI6000A tab, click on Read Local. The LEDs on the front of the PL1877A
strobe, and then the
PWR
and
BUSY
LEDs remain illuminated. Click on OK after the progress bar
reaches 100%.
After the Read ITI6000A tab menu has been completed, you are now ready to continue programming the
necessary parameters.