4. Reverse Burst Disable (necessary for signal search mode only)

Tone PL (reed type, TRN6177C and similar) - Remove the lead on the PL deck that comes from
J601, pin 1 (PL on-off from hang-up box) and solder it to Q406 base. Solder the supplied .01

µF RF

decoupling capacitor between base and emitter of Q406.
Connect JU401 to HD (Note: there are two JU401s shown on the board pictorial. The correct one for
this function is the one that grounds the emitter of Q409 when connected to pin HD.)
Tone PL (reedless type, TRN4237A and similar) - Remove the lead on the PL deck that comes
from J601, pin 1 (PL on-off from hang-up box) and solder it to U401, pin 36.
Remove the lead on the PL deck that comes from J601, pin 2 (hang-up box ground) and solder it to
the junction of C414 and R408 on the PL deck.
Remove R421 on the PL deck (between U401, pin 7, and pin 26).
Solder the supplied diode into the JU102 holes on the main circuit board (close to squelch control)
with the cathode toward mic PTT.
Digital PL (TRN 6207A and similar) - Remove the lead on the PL deck that comes from J601, pin
1 (on-off from hang-up box) and solder it to Q312 base. Connect JU302 to pin D.

The monitor function is now via the front panel and/or desk mic monitor switch. Connect the PL1877A
P1 radio cable to the base station P601 connector as follows, using the supplied male connector pins, as
applicable.

Pin 601 Pin # Color

Function

6

Red

TX PL disable return

6

Green/black

RX detector return

6

Blue/black

TX audio return


Twist the above listed leads together and solder to a short wire lead. Then strip a small section on the
black power lead close to the connector. Neatly solder the short lead from the returns to the stripped
section of the black power lead.

Pin 601 Pin #

Color

Function

5

Blue/white

TX audio (mic high)

13

Green/white

RX detector audio

3

Red/black

TX PL disable

10

Black

RX PL detect

8 White PTT

1

Orange

Reverse burst inhibit

2

Orange/black

Reverse burst inhibit return


N

OTE

: The orange and orange/black leads (reverse burst inhibit and return) need to be connected only in

the signal search mode.

If the PL1877A is to be dc powered, connect the red lead in the dc power cable to P601 pin 4, and the
black lead to P601 pin 6. Connect the other end of the dc power cable into the 5-pin DIN connector (DC
PWR) on the rear panel of the PL1877A. If the optional ac transformer and cable are to be used, install
the ac power connector into the 5-pin DIN connector (DC PWR) on the rear panel of the PL1877A.