PL1877A Microprocessor Radio Telephone Interconnect Parameter
Modification
105
12/10
Para-
meter
No.
Description
Control Digits
Refer to
Section on
Page:
16
Determines whether phone line battery
reversal or loss, to disconnect mobile
originated call is allowed.
0 = Don’t allow
1 = Allow
Default = 0
93
17
Determines whether phone line battery
reversal or loss, to disconnect landline
originated call is allowed.
0 = Don’t allow
1 = Allow
Default = 0
93
18
Determines whether the mobile user is
allowed to override the access time limit
with ***.
0 = Don’t allow
1 = Allow
Default = 0
94
19
Determines whether the *** command
resets the overall access timer to 1 minute
or the time specified by parameter 357.
0 = Resets timer to 1 minute
1 = Resets timer to duration
specified by parameter 357.
94
20
Enables or disables the triple key access
feature.
0 = Disable
1 = enable
Default = 0
92
21
Enables or disables parameter modification
from a remote DTMF telephone.
0 = Disable
1 = Enable
Default = 1
90
22
Enables or disables parameter modification
via a modem.
0 = Disable
1 = Enable
Default = 1
90
23
Determines whether a landline user can
disconnect a mobile originated call using
the DTMF # command.
0 = Disable
1 = Enable
93
24
Determines whether emergency call direct
access is enabled or disabled.
0 = Disable
1 = Enable
Default = 0
102
25
Determines whether revert from direct
access timer to overall access timer upon
detection of mobile carrier is enabled or
disabled.
0 = Disable
1 = Enable
Default = 0
100
26
Enables or disables multiple ringing to
mobiles.
0 = Disable
1 = Enable
Default = 0
103
27
Enables or disables mobile ring signaling
prior to direct access.
0 = Disable
1 = Enable
Default = 1
99
28
Enables or disables enhanced VOX
attention getting ticks.
0 = Disable
1 = Enable
84
29
Determines whether enhanced VOX,
landline transmit timer is enabled or
disabled.
0 = Disable
1 = Enable
84