PL1877A Microprocessor Radio Telephone Interconnect Parameter
Modification
107
12/10
Para-
meter
No.
Description
Control Digits
Refer to
Section on
Page:
46
Allows 9 as the first telephone digit.
0 = Don’t allow
1 = Allow
97
47
Allows 1 as the first telephone digit.
0 = Don’t allow
1 = Allow
97
48
Allows 0 as the first telephone digit.
0 = Don’t allow
1 = Allow
97
49
Determines whether toll restriction applies
to auto-dial numbers.
0 = Does not apply
1 = Applies
Default = 0
98
50
Determines whether * access command is
required from a landline user on line 1
before allowing direct channel access or
selective signaling input.
0 = Don’t require
1 = Require
Default = 1
101
51
Determines whether * access command is
required from attendant user before
allowing a direct channel access or
selective signaling input.
0 = Don’t require
1 = Require
Default = 1
101
52
Enable or disable SID on patch release.
0 = Disable
1 = Enable
95
53
Determines whether the mobile user is
restricted to using the auto-dial feature for
dialing telephone numbers.
0 = Don’t restrict
1 = Restrict
Default = 0
98
54
Allows a mobile user to access a busy
phone line with the *** command.
0 = Don’t allow
1 = Allow
Default = 0
103
55 Enables/disables
mobile modification of
auto-dial numbers.
0 = Disable
1 = Enable
Default = 1
90
56
Determines whether the station/repeater
enable feature is enabled or disabled.
0 = Disable
1 = Enable
Default = 0
103
57
Enables or disables a mobile users ability
to modify parameters with a DTMF
keypad.
0 = Disable
1 = Enable
Default = 0
90
58
Enable or disables landline direct channel
access.
0 = Disable
1 = Enable
Default = 0
99
59
Enable or disables attendant direct channel
access.
0 = Disable
1 = Enable
Default = 0
99