Mobile inactivity timer, Semi-private operation, Pl strip control – GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual
Page 101: Selectable features, Station identification (sid or cwid)

PL1877A Microprocessor Radio Telephone Interconnect Parameter
Modification
95
12/10
Mobile Inactivity Timer
Parameter Function
122
Mobile inactivity timer. This parameter determines how long the PL1877A keeps the 
phone line accessed without detection of mobile carrier. 
Valid range = 0-14. This parameter is x in the following equation: mobile inactivity 
timer = 30 seconds + x (30 seconds). 
If set to 15 (hexadecimal F), the mobile inactivity timer is disabled. 
Default = 0 
Semi-private Operation
PL Strip Control
Parameter Function
32
Automatically activate PL strip relay on access = 1 
Do not activate PL strip relay on access = 0 
Default = 0 
Selectable Features
Station Identification (SID or CWID)
Parameter Function
52
Disable SID on patch release = 0 
Enable SID on patch release = 1 
62
Do not transmit the SID if it is time to do so and no station PTT has occurred since the 
last SID transmission = 0 
Transmit the SID if it is time to do so and no station PTT has occurred since the last SID 
transmission = 1 
361
The time, in minutes, between SID transmissions. Valid range = 0–59 minutes. 
If this parameter is programmed to 0, periodic SID is disabled. 
501-512
Station ID (SID) - enter the SID in ASCII as shown in the table below. 
N
OTE
: ASCII equivalents are given in hexadecimal.