Dial tone detection, General call characteristics, Call timers – GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual
Page 100: Overall access timer
![background image](https://www.manualsdir.com/files/786950/content/doc100.png)
Parameter Modification
PL1877A Microprocessor Radio Telephone Interconnect
12/10 94
Dial Tone Detection
Parameter Function
64
Disable disconnection upon detection of dial tone for a land-line originated call = 0
Enable disconnection upon detection of dial tone for a land-line originated call = 1
Default = 0
General Call Characteristics
Parameter Function
13
Disable mobile call origination = 0
Enable mobile call origination = 1
Default = 1
14
Disable land-line call origination = 0
Enable land-line call origination = 1
Default = 1
15
Disable attendant call origination = 0
Enable attendant call origination = 1
Default = 1
Call Timers
Parameter Function
360
The length of time before disconnect that time out warning ticks are generated.
Valid range = 0–59 seconds.
If this parameter is programmed to 0, time-out ticks are disabled.
Default = 15
Overall Access Timer
Parameter Function
18
Don’t allow mobile user to override access time limit with *** command = 0
Allow mobile user to override access time limit with *** command = 1
Default = 0
19
*** command (entered during conversation) resets overall access timer to 1 minute = 0
*** command (entered during conversation) resets overall access timer to duration
specified by parameter 357 = 1
Default = 1
357
Overall access timer. Valid range = 1–59 minutes.
Any number greater than 59 sets the overall access time to an infinite duration.
Default = 1 minute