Serial port setup, Input/output – i/o settings - read iti6000a – GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual
Page 28

PC Programming
PL1877A Microprocessor Radio Telephone Interconnect
12/10 22
Serial Port Setup
The PL1877A can be programmed from the Local Port or the Remote Port. This parameter must be
entered to begin programming.
• If the PL1877A is installed in the same location as the computer used to program it, the serial port
selected should be Local. Refer to Input/Output - I/O Settings - Local Reading on page 24.
• If the PL1877A is located at a remote location, a modem must be installed at the correct serial port.
Select Modem Port. See the Modem Installation manual for complete information.
Make sure your COMM ports are connected properly.
Input/Output – I/O Settings - Read ITI6000A
• After the correct COMM port is selected, click on the Read ITI6000 tab.
N
OTE
: Once Read ITI6000 begins, you will not be able to close or switch from this window until the
read either finishes or fails unless you click on Cancel.
• Select Read Remote for a remote (modem) installation.
• Select Read Local for a Local installation. Programming information about Read Local follows the
Remote (modem) programming information on page 24.
When the progress bar reaches 100%, click on OK. The expanded main menu is now available that
allows you to complete your IAPS programming.