PL1877A Microprocessor Radio Telephone Interconnect Parameter
Modification
109
12/10
Para-
meter
No.
Description
Control Digits
Refer to
Section on
Page:
123
Determines the number of rings that the
PL1877A must receive before generating
ring signaling to the mobile.
Valid range = 1–9
Default = 1
88
124
Determines the function of programmable
GPI-1 (pin P1-14).
0 = GPI-1 unused
1 = Aux. carrier detect input
86
125
Determines the function of programmable
GPI-2 (pin P1-16).
0 = GPI-2 unused
1 = Aux. carrier detect input
86
126
Direct access duration - the number of 5-
second periods in the direct access time.
Valid range = 0–8
Default = 0
100
127
Enhanced VOX receive recovery delay -
the number of 50-ms periods in the delay
between transmitting and receiving
enhanced VOX mode.
Valid range = 0–8
84
128
The time, in seconds, that the PL1877A is
to pause and wait for a dial tone when the
pause character is encountered in an auto-
dial number.
Valid range = 0–7
Default = 5
98
129
Determines the “on” time for regenerated
digits.
Valid range = 0–8 (50–450
ms)
Default = 1
89
130
Rotary dial pulse rate.
Valid range = 0–9
0 = 9 pulses per second
1 = 6 pulses per second
2 = 7 pulses per second
3 = 8 pulses per second
4 = 10 pulses per second
5 = 11 pulses per second
6 = 12 pulses per second
7 = 13 pulses per second
8 = 14 pulses per second
9 = 20 pulses per second
Default = 0
89
131
The number of busy tone cycles that must
be received to cause the PL1877A to
disconnect during a mobile originated call.
When this parameter is set to 0, busy tone
detection is disabled.
Valid range = 1–15
Default = 0
93
133-138 Prefix to * landline access code - the
access code a landline user must enter as a
prefix to the * command, before being
granted direct channel access or selective
signaling privileges.
Valid range = 0–$D
101