beautypg.com

Running an omr test, En glish – Formax 6404 Series User Manual

Page 87

background image

An Example of OMR Code

In the figure the legend for the following example is shown. In this example, a set of 8

sheets with one selective feed and three sequence check marks is shown.

• The first position is used for the start mark which must be printed on every sheet.
• The second mark position is used for the insert/accumulate command. A printed

mark means insert, no mark means accumulate. Therefore the mark is printed on
the last sheet of the set.

• Position 3 is reserved for selective feed from the enclosure feeder. Print a mark on

position 3 when a selective feed from the enclosure feeder is required. The marks
are printed on the last sheet of the set.

• Position 4, 5 and 6 are used for the sequence check marks. In this case a three mark

sequence check is used.

Running an OMR test

To run an OMR test:

Before running an OMR test, select a job that uses OMR reading.

1.

In the Test menu, press the

[OMR test] button. The OMR test menu appears.

80

| Page 80 | jan-06-2012 13:58 |

7

En
glish