beautypg.com

En glish – Formax 6404 Series User Manual

Page 110

background image

Adjusting the enve-
lope insert fingers

on page 36

Check fingers posi-
tion, adjust if needed.

Fingers not correctly
adjusted.

System stops while
inserting (stoppage at
the inserting point).

Fold settings

on

page 50

Check fold settings.

Inserted document
too long for used en-
velope.

Verifying the Insert
Position

on page 37

Check envelope
specifications.

Envelope throat incor-
rect.

-

Eliminate faulty en-
velopes.

Envelope glued in-
side.

-

Eliminate faulty en-
velopes.

Window not glued
properly.

Filling the Sealing
Liquid Reservoir

on

page 20

Check water level,
refill if needed.

Water level low.

Flap not sufficiently
moistened.

Maintenance Sched-
ule

on page 90

Check brushes, re-
place if needed by the
extra soaked set.

Brushes dry.

Maintenance Sched-
ule

on page 90

Check brushes, clean
if needed.

Brushes dirty.

Filling the Sealing
Liquid Reservoir

on

page 20

Check the moistening
felt, refill water tray if
needed.

Moistening felt dry.

Maintenance Sched-
ule

on page 90

Check the moistening
felt, clean if needed.

Moistening felt dirty.

Maintenance Sched-
ule

on page 90

Replace brushes.

Brushes worn out.

Maintenance Sched-
ule

on page 90

Replace moistening
felt.

Moistening felt worn
out.

Fold settings

on

page 50

Check fold settings,
adjust if needed.

Inserted document
too big.

Envelope not always
ejected from sealer.

Verifying the Insert
Position

on page 37

Check adjustment of
envelope stop posi-
tion and fingers.

Document not insert-
ed deep enough.

Maintenance Sched-
ule

on page 90

Clean sealing area.

Sealing area dirty.

10

En
glish

103

| Page 103 | jan-06-2012 13:58 |