En glish – Formax 6404 Series User Manual
Page 61
![background image](https://www.manualsdir.com/files/785537/content/doc061.png)
• Stop on misread: define if the system should stop or not when a code is misread. In
case of “yes”, the system stops after a misread. The incorrect set is diverted. After
resetting the system, the final part of the set is also diverted and the system starts
processing again. The diverted set should be checked by the operator.
When “stop on misread” is set to “no”, the system does not stop after a misread.
The incorrect set is diverted. The final part of the set is also diverted and then the
system starts processing again. After 5 misreads in a row, the system stops and
an error code is generated.
• Stop on sheet overflow: define if the system should stop or not when a set exceeds
the maximum number of sheets, as defined at the "Max. sheets setting". In case of
“yes”, the system stops when the number is exceeded. The incorrect set is diverted.
After resetting the system, the final part of the set is also diverted and the system
starts processing again. The diverted set should be checked by the operator.
When “stop on sheet overflow” is set to “no”, the system does not stop when a set
exceeds the maximum number of sheets. The incorrect set is diverted. The final part
of the set is also diverted and then the system starts processing again.
• Max. sheets: use the arrow buttons to select the maximum amount of sheets in the
set of documents.
The maximum number of sheets in a set is 25. When the number
of sheets exceeds 8 or 10, depending on the fold, the document
can not be folded anymore. In this case, the maximum length of
sheets is 148 mm for a C5/6 envelope. Also make sure that the
fold is set to No fold. Ignoring this will certainly lead to stoppages.
When the maximum number of sheets exceeds the programmed
maximum number of sheets in a set, the system stops and
error VS:110 will be displayed. After removing the set and pressing
the
[Reset] button, the system will start and repeat the process
until an insert or divert mark is encountered, error VS:135 (final set
part) will be displayed.
54
| Page 54 | jan-06-2012 13:58 |
5
En
glish