Figure 3-27 gir remote policies prompt, Figure 3-28 entry channel switch rates screen, Set, as shown in figure 3-27. note – Comtech EF Data CDD-56X Series Vipersat User Manual

Page 59

background image

Chapter

3 -

Using the Command Line Interface (CLI)

3-25

MN/22137, rev 1

Vipersat Configuration

Set the Automatic Load Switch Rate to a value greater than the GIR to allow the

Remote to be automatically switched out of STDMA and into SCPC mode

when traffic exceeds the GIR. A Switch Rate of 0 will prevent the Remote from

being switched out of STDMA and into SCPC mode.

Figure 3-27 GIR Remote Policies prompt

The Remote Policies screen for an Entry Channel Hub type allows the SCPC

data rates and switch types to be specified for when the Remotes will switch and

the desired starting points for communications.

Figure 3-28 Entry Channel Switch Rates screen

Entering the Remote number at the command prompt in figure 3-28 allows the

SCPC Data Rate and the Switch Type for that Remote to be set, as shown in

figure 3-29. Switch type 0 corresponds to Load Switching; switch types 64

through 255 are user-defined, and must match VMS policies. When choosing

Load Switching as the Switch Type, the associated Remote must have the Load