Figure 3-27 gir remote policies prompt, Figure 3-28 entry channel switch rates screen, Set, as shown in figure 3-27. note – Comtech EF Data CDD-56X Series Vipersat User Manual
Page 59
Chapter
3 -
Using the Command Line Interface (CLI)
3-25
MN/22137, rev 1
Vipersat Configuration
Set the Automatic Load Switch Rate to a value greater than the GIR to allow the
Remote to be automatically switched out of STDMA and into SCPC mode
when traffic exceeds the GIR. A Switch Rate of 0 will prevent the Remote from
being switched out of STDMA and into SCPC mode.
Figure 3-27 GIR Remote Policies prompt
The Remote Policies screen for an Entry Channel Hub type allows the SCPC
data rates and switch types to be specified for when the Remotes will switch and
the desired starting points for communications.
Figure 3-28 Entry Channel Switch Rates screen
Entering the Remote number at the command prompt in figure 3-28 allows the
SCPC Data Rate and the Switch Type for that Remote to be set, as shown in
figure 3-29. Switch type 0 corresponds to Load Switching; switch types 64
through 255 are user-defined, and must match VMS policies. When choosing
Load Switching as the Switch Type, the associated Remote must have the Load