Comtech EF Data CDD-56X Series Vipersat User Manual

Page 33

background image

Chapter

2 -

Quick Start Configuration

2-11

MN/22137, rev 1

Initial Configuration

2. Enter R at the command prompt to toggle the Unit Role to either Hub or

Remote.

This parameter will determine the role the target CDD-56X will perform in

the network and what type of commands and functions it will receive from

the VMS.

3. Enter E to set the Expansion Unit value to either Yes or No.

When configured as an Expansion unit, either as a Hub (switched) or as a

Remote (mesh), the CDD-56X is set up so that all Demods are in SCPC

mode and available as resources for dedicated communications with the

other end of the satellite link.

4. Enter B at the command prompt to set the Network ID.

The Network ID that is assigned to the unit defines to what network the

target CDD-56X will belong. All units used in a network will have the

same Network ID. This parameter is used by the VMS to identify units

common to a network and allows the VMS to manage multiple networks,

each with its own unique network ID number.

5. Enter N at the command prompt to set the Unit Name.

6. Enter V at the command prompt to set the Receive Multicast Address.

This IP address is the multicast address assigned to the VMS and to all

units in the network that are managed by the VMS. The Receive Multicast

Address of this CDD-56X must match the Transmit Multicast Address that

has been assigned to the VMS.

7. Enter I at the command prompt to set the Managing IP Address.

The Managing IP Address is the IP address of the VMS server.

8. Management Security (Optional)

If this is an encrypted network, enter K at the command prompt to con-

figure Vipersat Management Security.

9. Enter H to go to the Home State Configuration menu screen, then enter

W to set the current configuration as the Home State.

10. Save the settings to flash by entering S at the command prompt.

This completes the initial configuration of a CDD-56X from the factory default

settings to a functioning, Vipersat-enabled unit. Additional configuration

parameters must be set depending on the network requirements for a specific

application.