beautypg.com

Ecmv2 mode, Ecmv2 mode -13, Figure 3-10 ecmv2 mode prompt – Comtech EF Data CDD-56X Series Vipersat User Manual

Page 47

background image

Chapter

3 -

Using the Command Line Interface (CLI)

3-13

MN/22137, rev 1

Vipersat Configuration

mitting back to the Hub. The Remotes transmit on a contention basis and should

a collision occur, the Remote will back off for a specified period and try again.

Once it obtains one of the available slots, the Remote will hold onto the slot

until it registers with the VMS and receives assignment into dSCPC, or until all

necessary transactions are completed. The slot is then released for use by

another Remote unit that is attempting to enter the channel.
Remotes can be set to one of four operating modes—Disable, Offline, Wait, and

Online—from the ECMv2 Mode command in the STDMA menu. In addition,

commands for setting parameters to accomodate any mismatches between the

Hub LNB and the Remote BUCs are presented: LNB LO Frequency (Hub),

BUC LO Frequency (Remote), and Satellite Conversion Frequency.

ECMv2 Mode

This menu item appears for Hub expansion and Remote expansion units operat-

ing in ECMv2 only.
Each unit can be set to a designated mode of operation in ECM:

• Disable – the ECM function for this unit is disabled.
• Offline – the unit will not transmit (muted).

This mode may be chosen for radio silence applications.

• Wait – the unit will register with the controller and remain in the ECM

wait queue without assignment for switching into dSCPC mode. This

mode may be chosen by operators who wish to manually control (via

diagnostic switch) when a unit is to be switched and utilize bandwidth

from the pool.

• Online – the unit will register with the controller and request dSCPC

bandwidth for switching.

In order for a unit to automatically switch into SCPC mode and pass data traffic,

the ECMv2 Mode must be set to Online.

Figure 3-10 ECMv2 Mode prompt

Tip: For purposes of commissioning the terminal with a continuous carrier, the

Entry Channel mode can be set temporarily to Disable. Once this process

is completed, set the Remote back to the desired mode for normal

operation.