beautypg.com

Base, Remote count, Base -23 remote count -23 – Comtech EF Data CDD-56X Series Vipersat User Manual

Page 57: Figure 3-25 base remote display prompt

background image

Chapter

3 -

Using the Command Line Interface (CLI)

3-23

MN/22137, rev 1

Vipersat Configuration

• R = Removed – This Remote is currently removed from the burstmap.

When displayed, this status indicates that the Hub has removed this remote

from the burstmap due to a communications fault.

• D = Disabled – This Remote is currently disabled and is not in the

burstmap.

This status will be displayed when a remote is manually disabled by the

operator or administrator.

• S = Switched – This Remote is currently switched into SCPC mode.

When displayed, this status indicates that the VMS has automatically

switched the remote out of the burstmap and into SCPC operation.

• H = Home State Revert – This Remote is not currently receiving burst

maps. When a remote, stuck in SCPC mode by failure to receive a VMS

revert command, sees the burst map with this flag set, it will automatically

revert to its home state and STDMA mode.

• CF – This Remote has not sent an acknowledgement to the burst controller

since it was enabled.

Most commonly, either a B or an S will be displayed, as a typical Remote

will be either Bursting or Switched out to the dSCPC pool.

Base

Entering a B at the command prompt in figure 3-23 allows entering the Remote

number to start displaying remotes in this menu screen. Entering the number 1,

as shown in figure 3-23, displays nine remotes, 1 through 9. If the number 4 had

been entered, the display would show the nine remotes starting with Remote 4

(i.e., remotes 4 through 12).

Figure 3-25 Base Remote Display prompt

Remote Count

The Remote Count menu item in figure 3-23 is an information-only display

showing the total number of Remotes that currently belong to the STDMA

group for this Hub burst controller.