Chapter

3 -

Using the Command Line Interface (CLI)

3-17

MN/22137, rev 1

Vipersat Configuration

For Dynamic Cycle and GIR configurations, the number of cycles is automati-

cally set to one in order to ensure optimum performance for these Hub types.
This parameter can be modified by entering a C at the command prompt to

display the dialog shown in figure 3-15.

Figure 3-15 Cycles per Burst Map prompt

Slot Guardband

This menu item, which appears for all Hub configurations, displays the current

length of the Slot Guardband in milliseconds and in bytes for the remotes in the

group. The Slot Guardband is the amount of time between the point when one

remote completes transmitting data and the point when the next remote in the

cycle begins transmitting. This prevents the remote from overrunning the next

terminal in the cycle. The setting for this parameter should be obtained using the

Vipersat STDMA calculator.

Tip: For a copy of the latest Viper Calculator, contact a Comtech Vipersat

Networks representative.

This value can be modified by entering a G at the command prompt to display

the dialog shown in figure 3-16 and entering a new value.

Figure 3-16 Slot Guardband prompt

Note: The value entered at the command line in figure 3-16 is in milliseconds.

The corresponding value expressed in bytes is calculated by the