Comtech EF Data CPA User Manual
Page 95
CPA C-Band Indoor Solid State Power Amplifier
Revision 1
Ethernet-based Remote Product Management
MN/CPA-IN.IOM
6–19
Figure 6-9. Config | Redundancy page (cont.)
Page with Manual Redundancy Mode selected
Redundancy Mode
This read-only section provides the following information:
•
The active system operating status is identified as ON or OFF.
When OFF, the configuration sections that follow on this page are not accessible
•
The active operating unit – i.e., the Primary SSPA or Backup SSPA – is identified.
•
The active redundancy configuration – 1:1 or 1:2 – is identified.
Automatic/Manual Mode (1:1 or 1:2 Redundancy)
Use the drop-down list to select the backup operation mode as Automatic or Manual.
Priority Select (1:2 Redundancy only)
Use the provided drop-down list to select the desired Backup SSPA as SSPA#1 or SSPA#2.
Note that, for 1:1 configurations, the priority unit number is always fixed as SSPA#1.
Set the desired operating mode and backup priority (1:2 redundancy only), and then click
[Change Redundancy Config] to save these settings.
Backup Mode (1:1 or 1:2 Redundancy, Manual Mode only)
When Automatic Mode has been selected as the Operating Mode, this section of
the Redundancy page is inaccessible.