CPA C-Band Indoor Solid-State Power Amplifier

Revision 1

Front Panel Operation

MN/CPA-IN.IOM

5–13

Use the

◄ ►

arrow keys to select Auto/Manual Mode or Backup Mode, and then press ENTER.

If 1:2 Redundancy is recognized:

Config: Auto/Manual Mode

Backup Mode Priority

Use the

◄ ►

arrow keys to select Auto/Manual Mode, Backup Mode, or Priority, and then press

ENTER.

The operations that follow are typical for both 1:1 and 1:2 redundant operations unless otherwise

indicated.

CONFIG: Redundancy

Auto/Manual Mode

Operating Mode: Manual

Automatic (◄ ► E)

Select Manual or Automatic using the

◄ ►

arrow keys, and then press ENTER.

CONFIG: Redundancy

Backup Mode

This submenu is enabled only in Remote Local mode, and with Redundancy

Auto/Manual Mode set to Manual. If you attempt to access this submenu either

while in Remote Serial or Remote Ethernet mode, or with Redundancy

Auto/Manual Mode set as Automatic, this submenu is disabled and, in its place, the

following message displays:

NOT IN MANUAL MODE OR

NOT ACTIVE

Otherwise:

SSPA #1 OFFSET: X.XX dB

Active Backup: NO

For 1:2 configurations only: On the top line, use the

▲▼ arrow keys to select the desired

Backup CPA (i.e., SSPA #1 or SSPA #2). For 1:1 configurations, note that this number is

always fixed as ‘1’.

For 1:1 and 1:2 configurations:

On the top line, set the dB offset used for Gain Equalization for the selected Backup CPA. Use

the

◄ ►

arrow keys to first select the numeral to edit, and then use the

▲▼ arrow keys to

edit that digit. The valid range, in dB, is -7.00 to +7.00.

On the bottom line, use the ▲▼ arrow keys to set operation of the specified Backup CPA: