CPA C-Band Indoor Solid State Power Amplifier

Revision 1

Appendix A

MN/CPA-IN.IOM

A–4

Issue

Possible Cause(s)

Solution(s)

No RF output or ≤ output

level.

1. Mute function activated.
2. Amplification = Off feature activated.
3. Large customer attenuation values

selected.

4. Input power level not correct.
5. Faulty input connections from 9V

supplies.

6. Fault SSPA control cable or

connection.

1. Check the Configuration menu to determine if

mute function has been activated. Mute = On

Means that the unit is muted. Turn Mute

feature to Off to allow RF amplification of the

input signal.

2. The Amplification = Off feature allows for

lower current draw from the prime power

source under standby conditions. To obtain

RF output, ensure that this feature is set to

Amplification = On.

3. Check the Attenuation = XX setting in the

Configuration menu. Lower value to get more

gain.

4. Use the input sample port on the front panel

to determine that the input power level is as

specified. Remove and replace the input

cable.

5. Use the Monitor menu to check the internal

level of the PS1 and PS2. The levels should

be near 9V. If not correct, use a voltmeter to

measure the voltage where the #8 wires enter

the amplifier unit. With Unit Off, tighten

connections if necessary.

6. Check the 25-pin ribbon cable connection at

the amplifier module and at AS/0200 PCB.

Tighten as necessary.

Failed SSPA amplifier

module.

This can usually be determined by using

the Monitor menu to check the DC

current levels being drawn by each

transistor inside the amplifier module.

Any transistor (QX) current that is 50%

more or less than normal would probably

indicate a failure.

Nominal Values:
Q1 =

20mA

Q2 =

100 mA

Q3, Q4 =

1.0 A

Q5, Q6, Q7 =

2.0 A

Q8 to Q18 =

2.25 A

There are no user serviceable parts inside the

amplifier module. Return to factory for repair.

No remote control

communication

1. Incorrect cable connections.
2. Improper communication settings

between ISSPA and controlling

terminal.

3. Entry mode of unit set to LOCAL.

1. Ensure cable is connected properly.
2. Check settings of ISSPA along with remote

control terminal software.

3. Change entry mode setting in Configuration

menu to Remote.