beautypg.com

Comtech EF Data CPA User Manual

Page 109

background image

CPA C-Band Solid State Power Amplifier

Revision 1

Serial-based Remote Product Management

MN/CPA-IN.IOM

7–9

Parameter Type

Command

(Instr Code and

Qualifier)

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes, i.e., ASCII codes between 48 and 57)

Query

(Instr Code and

Qualifier)

Response to Query

(Target to controller)

Force Back-Up

State

FBU=

1 byte,

value of 0, 1, 2

Command or Query (backup unit only).
When ESW is off, force one of the online units to be a back-up for maintenance and test

purposes, where:

0 – no force back-up

1 – force SSPA 1 to go offline

2 – force SSPA 2 to go offline

FBU?

FBU=x

(see description)

Retrieve

Firmware Number

N/A

variable length, alpha

numerical

Query only.
Gets the Firmware Number of the unit.

Example: >0001/FRW=

Boot:

FW-0000085;2.0.0a;02/21/08

Bulk:

FW-0000086;2.0.0a;02/21/08

FW-0000087;2.0.0a;02/21/08

FW-0000088;2.0.0a;02/21/08

FRW?

(see Description of

Arguments)

Global Amplifier

Configuration

GAC=

variable length, alpha

numerical

Command or Query.
Used to set up and query the global status of the amplifier.
Example: GAC=aa.aabcdef‘cr’ where:

aa.aa = Customer Attenuation (ATT)

b = RF power amplifier state (AMP)

c = mute state (MUT)

d = online status (RED)

e = redundancy mode (ESW)

f = Auto Fault Recovery (AFR)
NOTE: If it is not applicable, it will display x.

GAC?

GAC=x….x

(see Description of

Arguments)

Initialize Events

Pointer

IEP=

None

Command only.
Resets internal pointer to allow RNE? Queries to start at the beginning of the stored events log.
Example: IEP=

N/A

N/A

IP Address

IPA=

18 bytes

Command or Query.
Used to set the IP address and network prefix for the 10/100 BaseTx Ethernet management

port, in the format xxx.xxx.xxx.xxx.yy, where:

xxx.xxx.xxx.xxx is the IP address, and

yy is the network prefix (8..30)
Example: IPA=010.006.030.001.24

IPA?

IPA=

xxx.xxx.xxx.xxx.yy

Gateway

Address

IPG=

15 bytes

Command or Query.
Used to set the Gateway IP address for the

10/100 Base Tx Ethernet management port, in the format xxx.xxx.xxx.xxx, where:

xxx.xxx.xxx.xxx is the IP address
Example: IPG = 010.006.030.001

IPG?

IPG = xxx.xxx.xxx.xxx