3 config | redundancy – Comtech EF Data CPA User Manual
Page 94
CPA C-Band Indoor Solid State Power Amplifier
Revision 1
Ethernet-based Remote Product Management
MN/CPA-IN.IOM
6–18
Reference Frequency Adjust (0-255)
This section is not available when the External Reference hardware option is not
installed.
Enter an adjustment value from 0 to 255., and then click [Adjust] to save.
6.4.4.3.3
Config | Redundancy
Comtech EF Data SSPAs are designed to automatically sense and configure into
Redundancy Mode when the redundant loop cable is connected between the two
(i.e., 1:1) or three (i.e., 1:2) SSPAs comprising the redundant subsystem. The
designation of each CPA in a redundant subsystem is determined automatically
via the redundancy interface cable connected – polling on the dedicated
redundancy bus will not begin until the redundancy loop cable is connected.
Use this page to control the operational parameters for redundant operations. The page
identifies the active Redundancy Mode as “OFF”, “ON, SSPA Backup Unit, 1:1” or “ON, SSPA
Backup Unit, 1:2”, and the appearance of the page itself varies depending on its Operating
Mode.
Figure 6-8. Config | Redundancy page
(Top) Page in Standalone Configuration (no redundant units recognized by system)
(Bottom) Page with Automatic Redundancy Mode selected