beautypg.com

4 packet structure, 1 start of packet – Comtech EF Data CPA User Manual

Page 103

background image

CPA C-Band Solid State Power Amplifier

Revision 1

Serial-based Remote Product Management

MN/CPA-IN.IOM

7–3

7.4

Packet Structure

Controller-to-Target

Start of Packet

Target Address

Address Delimiter

Instruction Code

Code Qualifier

Optional Arguments

End of Packet

<

ASCII code 60

(1 character)

(4 characters)

/

ASCII code 47

(1 character)

(3 characters)

= or ?

ASCII codes 61 or 63

(1 character)

(n characters)

Carriage Return

ASCII code 13

(1 character)

Example:

<0412/MUT=1{CR}

Target-to-Controller

Start of Packet

Target Address

Address Delimiter

Instruction Code

Code Qualifier

Optional Arguments

End of Packet

>

ASCII code 62

(1 character)

(4 characters)

/

ASCII code 47

(1 character)

(3 characters)

=, ?, !, or *

ASCII codes

61, 63, 33, or 42

(1 character)

(From 0 to n characters) Carriage Return, Line

Feed

ASCII codes 13,10

(2 characters)

-OR-

Carriage Return, Line

Feed

ASCII codes 13,10

(3 characters)

Example:

>0412/MUT=1{CR}{LF}

If it is an error message or an old remote command, ‘]’ will show at the end.

Example:

>1?ATT_INVALID PARAMETER'cr''lf']

7.4.1 Start of Packet

Controller-to-Target: This is the character ‘<’ (ASCII code 60).

Target-to-Controller: This is the character ‘>’ (ASCII code 62).

Because this is used to provide a reliable indication of the start of packet, these two characters may not appear anywhere else within the

body of the message. The only exceptions are in command RMS and CMS where the response is “FWPWR=<19.0”.