beautypg.com

3 utility connections, 1 sample port connectors (front panel), 2 j4 | redundant loop connector – Comtech EF Data CPA User Manual

Page 39

background image

CPA C-Band Indoor Solid State Power Amplifier

Revision 1

Connectors and Pinouts

MN/CPA-IN.IOM

3–5

3.3

Utility Connections

3.3.1

Sample Port Connectors (Front Panel)

These ports are Type ‘N’ female connectors, providing easy access

–20 dBc and –40 dBc test points on the ISSPA front panel.

Name

Connector Type

Description

Direction

SAMPLE | OUTPUT

Type ‘N’ Female

–20 dBc Sample Test Port

Input

SAMPLE | INPUT

–40 dBc Sample Test Port

Output

3.3.2

J4 | REDUNDANT LOOP Connector

Appendix B. ISSPA REDUNDANT OPERATIONS

This is a 19-pin circular connector, type MS3112E14-19S. The pin-out

specification is contained in Table 3-2. This receptacle is used only in 1:1

and 1:2 redundant configurations.

Mating connector: ITT KPT06J14-19P or MS3116J14-19P

Table 3-2. J4 Redundancy Loop Connector Pinout

Pin #

Description

Pin #

Description

A

Loop In 1

L

SumFlt 2 NO

B

ADDR 2

M

SumFlt 2 Common

C

Loop In 2

N

Local Loop Out

D

Loop Out 2

P

SumFlt 1 NO

E

ADDR Common

R

SumFlt 1 Common

F

ADDR 1

S

Local SumFlt Common

G

Loop Out 1

T

Local SumFlt NC*

H

HSB +RX/TX

U

No Connect

J

HSB – RX/TX

V

No Connect

K

Local Loop In

*Connected to Pin ‘S’ if unit is powered on and no fault present