beautypg.com

Comtech EF Data CPA User Manual

Page 112

background image

CPA C-Band Solid State Power Amplifier

Revision 1

Serial-based Remote Product Management

MN/CPA-IN.IOM

7–12

Parameter Type

Command

(Instr Code and

Qualifier)

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes, i.e., ASCII codes between 48 and 57)

Query

(Instr Code and

Qualifier)

Response to Query

(Target to controller)

Retrieve

Configuration

Status

N/A

variable length, alpha

numerical

Query only.
Used to Query the configuration status of the unit.

Example: RCS=’cr’

ATT=10.00

AMP=1

MUT=0

RED=1

ESW=0

AFR=1

XRF=N/A

NOTES:

XRF = External reference status, where:

N/A = no external reference

05M = 5 MHz

10M = 10 MHz

XRF will always be N/A if the internal reference oscillator option is not installed.

If a parameter it is not applicable, it will display x. Example: ESW=x

RCS?

RCS=x….x

(see Description of

Arguments)

Online Status

N/A

1 byte,

value of 0, 1

Query only.
Online status (applies only to redundancy), where:

0 = Offline

1 = Online
Example: <0001/RED?’cr’

>0001/RED=1’cr’’lf’

RED?

RED=x

Reference

Oscillator Adjust

REF=

3 bytes,

numerical

Command or Query.
Ref Osc Adjust, between 000 and 255.

Resolution 001. (Optional installation)
Example: REF=087
Note: REF cannot be adjusted when the unit is locked to an external reference source.

REF?

REF=x

(same format as

command arguments)

Retrieve

Equipment Type

N/A

variable length,

alphanumerical

Query only.
The unit returns a string indicated the Model Number and the value of internal software revision

installed.
Example: RET=AR1481457-80 REF BUC VER: 2.1.3

RET?

RET=x….x

(see Description of

Arguments)