2 installing the cpa isspa into a rack enclosure – Comtech EF Data CPA User Manual

Page 30

background image

CPA C-Band Indoor Solid State Power Amplifier

Revision 1

Installation

MN/CPA-IN.IOM

2–2

2.2 Installing the CPA ISSPA Into a Rack Enclosure

The CPA ISSPA is designed to be rack-mounted in a standard 19-inch (480 mm) wide rack or

cabinet (Figure 2-1). Handles at the front of the ISSPA facilitate easy installation into and

removal from the rack.

Use, as required:

A user-supplied standard rack-mounted shelf (standalone only);

User-supplied screws to secure the front panel to the rack enclosure threaded front

mounting rails;

Comtech EF Data’s optional FP/SL0004, FP/SL0006, FP/SL0007, or FP/SL0008 Bearingless

Rack Slide Set (Figure 2-2).

When mounting the ISSPA into a rack enclosure:

PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be

connected to the protective earth connection at all times. It is therefore imperative

that the unit is properly grounded, using the ground stud provided on the unit rear

panel, during installation, configuration, and operation.

PROPER AIR VENTILATION IS REQUIRED. In a rack system where there is high

heat discharge, provide forced-air cooling with top- or bottom-mounted fans or

blowers.

o

Two internally mounted exhaust fans provide cooling – cool air is taken in

through the front panel and exhausted out the rear panel. Locate the CPA

so that the input and output airflow paths are not obstructed or

restricted – this will minimize the amplifier operating temperature.

o

Air temperature inside the rack enclosure should

never

exceed 50

°

C

(122

°

F).

For information about custom rack enclosures, contact Comtech EF Data

Customer Support during normal business hours.