2 config: amp – Comtech EF Data CPA User Manual
Page 67
CPA C-Band Indoor Solid-State Power Amplifier
Revision 1
Front Panel Operation
MN/CPA-IN.IOM
5–11
5.3.1.2 CONFIG: Amp
The CONFIG: AMP commands are valid only in Remote Local mode. If you
attempt to edit any of the AMP settings while in Remote
Serial or Remote
Ethernet mode, the following message displays:
THIS UNIT IS CURRENTLY
IN REMOTE MODE!!
Amp: Attenuation State
Mute (◄ ► E)
Use the
◄ ►
arrow keys to select Attenuation, State, or Mute, and then press ENTER. Note the
following:
Selection
Description
Attenuation
Input and displays the CPA attenuation setting which is selected between 0.00
dB to 20.00 dB in 0.25 dB steps. The default setting is 10.00 dB.
State
Controls the operational state of the CPA amplifier. The default is ON.
Mute
Provides CPA mute control. The default is OFF.
CONFIG: Amp
Attenuation
Attenuation: 10.00 dB
Use the
▲▼ arrow keys to select a CPA attenuation value between 0.00 dB to 20.00 dB (in 0.25
dB steps), and then press ENTER. The default setting is 10.00 dB.
CONFIG: Amp
State
Amplifier: OFF ON
(◄ ► E)
Use the
◄ ►
arrow keys to select the Amplifier State as OFF or ON, and then press ENTER.
CONFIG: Amp
Mute
Amp Mute: OFF ON
(◄ ► E)
Use the
◄ ►
arrow keys to select the Amplifier Mute control as OFF or ON, and then press
ENTER.