CPA C-Band Indoor Solid State Power Amplifier

Revision 1

Appendix B

MN/CPA-IN.IOM

B–13

Case 2. Backup

Online unit(s)

1.

With the Backup Unit forced to be the active unit, adjust the Offset Value in the CONFIG:

Redundancy menu to roughly the difference measured previously. This will be a positive

(+) number.

2.

Toggle between the online and Backup Units as being the active path by forcing and un-

forcing a backup through the Backup Unit’s CONFIG: Redundancy SSPA#1 menu.

Make sure the output levels measured are equal. If necessary, re-adjust the Offset Value

until equal levels are measured. (Note that the Backup Unit’s total attenuation level as

now indicated in the CONFIG: Amp Attenuation menu will be equal to the setting of

the Online Unit plus the Offset Value.)

For Example:

Online Unit Output Level

47.00 dBm

Backup Unit Output Level

48.75 dBm

Backup Unit Offset Value

0.00 dBm

Online Attenuation Setting

3.00 dB

AFTER TOGGLING AND ADJUSTING:
Backup Offset Value

+1.75 dB

New Equalized Output Level

47.00 dBm

Backup Attenuation Setting

4.75 dB (3+(+1.75) = 4.75)