beautypg.com

Comtech EF Data CPA User Manual

Page 111

background image

CPA C-Band Solid State Power Amplifier

Revision 1

Serial-based Remote Product Management

MN/CPA-IN.IOM

7–11

Parameter Type

Command

(Instr Code and

Qualifier)

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes, i.e., ASCII codes between 48 and 57)

Query

(Instr Code and

Qualifier)

Response to Query

(Target to controller)

Part Number

N/A

Various 1-96 bytes,

alpha-numeric

Query only.
Returns the Comtech EF Data part number of the unit. This part number is the unit’s

DOTCODE at the time it was manufactured. The DOTCODE may be up to 96 printable ASCII

characters long.
Example: <1/PNM?’cr’

>0001/PNM=HPODC0.350WRSW00’cr’’lf’

PNM?

PNM=x….x

(see Description of

Arguments for return

string)

Priority Select

PRI=

1 byte,

value of 1, 2

Command or Query (backup unit only).
This command allows the user to assign priority when operating in a 1:2 redundant subsystem.

This command provides arbitration in the event that both primary SSPAs are faulted

simultaneously.
Example: PRI=1

PRI?

PRI=x

(same format as

command arguments)

Retrieve

Alarm Status

N/A

variable length, alpha

numerical

Query only.
Used to Query the Alarm status of the unit.

Example: <0001/RAS?

>0001/RAS=

+28=FT

+15=OK

+7.5=OK

+5=OK

-5=OK

RF_PS1=OK

RF_PS2=xx

TEMP1=OK

TEMP2=xx

LTEMP=xx

SHTD=OK

FAN1=OK

FAN2=OK

BUCLD=OK

XRFLD=OK

TRMST=YS

If it is not applicable, it will display xx.

FT – fault AL – alarm MS – masked YS – yes

RAS?

RAS=x….x

(see Description of

Arguments)

Reboot

RBT=

1 byte

Command only.
Soft Reboot

1 = Reboot System

Example: RBT=1

N/A

N/A