CPA C-Band Solid State Power Amplifier

Revision 1

Serial-based Remote Product Management

MN/CPA-IN.IOM

7–13

Parameter Type

Command

(Instr Code and

Qualifier)

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes, i.e., ASCII codes between 48 and 57)

Query

(Instr Code and

Qualifier)

Response to Query

(Target to controller)

FET Current

status

N/A

variable length

Query only.
Used to display all the FET currents.

Q01 and Q02 are in mA.

All other FETs are in Amps.

If it is not applicable, it will display xx.x.
Example: RFS?

Q01=xx.x’cr’

Q02=xx.x’cr’

Q03=xx.x’cr’

Q04=xx.x’cr’

Q32=xx.x’cr’

Q33=xx.x’cr’

Q34=xx.x’cr’’lf’

RFS?

RFS=x….x

(see Description of

Arguments)

Retrieve

Maintenance

Status

N/A

variable length, alpha

numerical

Query only.
Used to query the maintenance status of the unit.

Example: <0001/RMS?

>0001/RMS=

V+28=+27.8

V+15=+15.0

V+7.5=+7.8

V+5=+5.0

V-5=-5.0

RF_PS1=09.9

RF_PS2=10.0

TEMP1=+09.0

TEMP2=-10.0

LTEMP=+10.0

FWPWR=029.0

RVPWR=<12.0

REFVT=+04.3
If it is not applicable, it will display xx.x – Example: TEMP2=xxx.x

RMS?

RMS=x….x

(see Description of

Arguments)