beautypg.com

1 j3 power ac connector on legacy product cpa-350, 2 optional direct current operation – Comtech EF Data CPA User Manual

Page 45

background image

CPA C-Band Indoor Solid State Power Amplifier

Revision 1

Connectors and Pinouts

MN/CPA-IN.IOM

3–11

3.4.1.1 J3 Power AC Connector on Legacy Product CPA-350

The J3 AC prime power input connector for the CPA-350 legacy product is a 3-inch circular

connector, type CA3102E20-19PB FMLB A. A mating connector, type CA3106E20-19SB, is

provided. The pinout specification for this J3 connector and its mate is as follows:

Pin #

Description

A

Ground

B

Line 2

C

Line 1

Note that Ground Pin ‘A’ is of the first make, last break type.

3.4.2

Optional Direct Current Operation

MAKE SURE TO CONNECT ONLY THE CORRECT INPUT VOLTAGE AS SPECIFIED BY THE

REAR PANEL LABEL (-48VDC NOMINAL OR -24VDC NOMINAL)!

One of two independent DC power offerings is available – the correct nominal voltage is

indicated by a rear panel label:

-48VDC (38 to 65V) nominal

-OR-

-24VDC (18 to 36V) nominal

The input receptacle is type CA3102E20-22PB. The mating connector, type CA3106E20-22SB, is

provided. The pinout specifications are as follows:

Pin # Description

A

+VDC

C

Ground

E

-VDC

B,D,F

Unused

Alternately, the ground connection can be made with the external chassis ground connector.