beautypg.com

Comtech EF Data CPA User Manual

Page 115

background image

CPA C-Band Solid State Power Amplifier

Revision 1

Serial-based Remote Product Management

MN/CPA-IN.IOM

7–15

Parameter Type

Command

(Instr Code and

Qualifier)

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes, i.e., ASCII codes between 48 and 57)

Query

(Instr Code and

Qualifier)

Response to Query

(Target to controller)

Remote Address SPA=

4 byte,

numerical

Command or Query.
Set Physical Address-between 0001 to 9999.

Resolution 0001
Example: SPA=0412

SPA?

SPA=xxxx

(same format as

command arguments)

Set RTC Time

TIM=

6 bytes,

numerical

Command or Query.
A command in the form hhmmss, indicating the time from midnight, where hh = hours, between

00 and 23; mm = minutes, between 00 and 59, and ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59 seconds from midnight.

TIM?

TIM=xxxxxx

(same format as

command arguments)

Temperature

N/A

4 bytes

Query Only.
Returns the temperatures of the heat sink in the form of a sign byte followed by 3 bytes for the

temperature.
Example: TMP=+26.0

TMP?

TMP=sxxx

(see Description of

Arguments)

Time Protocol

Enable

TPE=

1 byte

Command or Query.

Used to enable or disable the Time Protocol, where:

0 = Time protocol disabled

1 = Time protocol enabled

Example: TPE=1 (Time protocol enabled)

TPE?

TPE=x

(see Description of

Arguments)

Time Protocol

Server

TPS=

15 bytes

Command or Query.

Used to set the Time Server IP address for the Unit Tx Ethernet management port, in the

format: xxx.xxx.xxx.xxx, where:

xxx.xxx.xxx.xxx is the Time server IP address

Example: TPS=192.168.001.005

TPS?

TPS= xx.xxx.xxx.xxx.yy

(see Description of

Arguments)