2 monitor – Comtech EF Data KST-2000A/B User Manual
Page 93
Ku-Band Satellite Transceiver
Revision 9
Operation
MN/KST2000AB.IOM
5–9
5.3.2
Monitor
The SELECT: MONITOR (Figure 5-6) menu is accessible from the SELECT menu.
When the MONITOR menu is entered, press [
W
] or [
X
] to select the desired function.
Each monitor function is displayed in real time for as long as it is selected.
Figure 5-6. Monitor Menu
The following listing describes each monitor function in detail.
Function
Description
U/C TEMP
Up converter temperature monitor.
Range: -40 to +90
° C (-40 to 194° F)
D/C TEMP
Down converter temperature monitor.
Range: -40 to +90
° C (-40 to 194° F)
HPA TEMP
HPA temperature monitor.
Range: -40 to +90
° C (-40 to 194° F)
M&C TEMP
M&C temperature monitor.
Range: -40 to +90
° C (-40 to 194° F)
PWR FCTR
The PWR FCTR is a power factor of the output power of
the CEFD HPA. In actuality, power factor is a very
close indication of the output power. This function is
only available with Comtech supplied SSPAs.
SUM FLTS
SUM FLTS are the summary faults of the complete
KST-2000A/B system. If there are any faults present,
they can be seen via a FLT indication in this menu.