8 monitor and control (m&c) – Comtech EF Data KST-2000A/B User Manual
Page 71
Ku-Band Satellite Transceiver
Revision 9
Operation
MN/KST2000AB.IOM
3–23
The microcontroller performs several operations on the reference assembly.
• It monitors the external reference status, and if an external input is detected, will
try to frequency-lock the 10 MHz oscillator.
• It monitors the 10 MHz oscillator oven current to determine when the oscillator
is warmed enough to provide a stable output.
• It sends control words to the 72 MHz PLL.
• It gathers and reports fault and status information to the KST-2000A/B M&C as-
sembly.
3.8
Monitor and Control (M&C)
The Monitor and Control (M&C) monitors the KST-2000A/B and provides configuration
updates to the up converter, down converter, and HPA when necessary. Refer to
Figure 3-13.
Figure 3-9. Monitor and Control (M&C) Block Diagram
The KST-2000A/B configuration parameters are maintained on battery locked RAM,
which provides recovery after power down.
The M&C functions include extensive fault and status reporting, as well as 1:1 redun-
dancy logic. All KST-2000A/B functions are accessible through the remote communica-
tions interface.
RAM
232 / 422
LED
EXT
INPUT
EXT
OUTPUT
FAULT
RELAY
ROM
1:1
CONTROL
STATUS
485
MODULE
COMM
M&C
LNA
CTRL
TEMP
RAM
ANALOG
MON
EXT
IN
MON
KEYPAD
DISPLAY
I2C