beautypg.com

Comtech EF Data KST-2000A/B User Manual

Page 174

background image

Ku-Band Satellite Transceiver

Revision 9

FSK Remote Control Commands

MN/KST2000AB.IOM

E-22

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments for
Command or
Response to
Query

Description of arguments
(note that all arguments are ASCII numeric codes, that is,
ASCII codes between 48 and 57)

Response to Command (target to controller)

Query
(Instruction
Code and
qualifier)

HPA Stored
Faults (8 Watt)

n.a.

7 bytes

Query only.
>add/HSF=ABCDEFG’cr’’lf’ or
>add/HSF=NO_FAULT’cr’’lf’

Where: A=Overtemperature Status, 0=OK, 1=FLT

B=9.75V Status, 0=OK, 1=FLT
C=-5V Status, 0=OK, 1=FLT
D=BV1 Summary Status, 0=OK, 1=FLT
E=BV2 Summary Status, 0=OK, 1=FLT
F=BV3 Summary Status,. 0=OK, 1=FLT
G=Interprocessor comm. Status, 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)

HSF= (message ok)
HSF? (received ok, but invalid arguments
found)
HSF* (message ok, but not permitted in current
mode)

HSF?

HPA Stored
Faults (25 Watt)

n.a.

13 bytes

Query only.
>add/HSF=ABCDEFGHIJKLM’cr’’lf’ or
>add/HSF=NO_FAULT’cr’’lf’

Where: A=Overtemperature Status, 0=OK, 1=FLT

B=9.75V Status, 0=OK, 1=FLT
C=-5V Status, 0=OK, 1=FLT
D=BV1 Summary Status, 0=OK, 1=FLT
E=BV2 Summary Status, 0=OK, 1=FLT
F=BV3 Summary Status, 0=OK, 1=FLT
G=BV4 Summary Status, 0=OK, 1=FLT
H=BV5 Summary Status, 0=OK, 1=FLT
I=BV6 Summary Status, 0=OK, 1=FLT
J=BV7 Summary Status, 0=OK, 1=FLT
K=BV8 Summary Status, 0=OK, 1=FLT
L=BV9 Summary Status, 0=OK, 1=FLT
M=Interprocessor Comm. Status, 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)

HSF= (message ok)
HSF? (received ok, but invalid arguments
found)
HSF* (message ok, but not permitted in current
mode)

HSF?