Revision 9

FSK Remote Control Commands

MN/KST2000AB.IOM

E-19

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments for
Command or
Response to
Query

Description of arguments
(note that all arguments are ASCII numeric codes, that is, ASCII
codes between 48 and 57)

Response to Command (target to
controller)

Query
(Instruction
Code and
qualifier)


Where:

2W SSPA – Item D=BV1

8W SSPA – Item D=BV1|BV2|BV3
16W SSPA – Item D=BV1|BV2|BV3|BV4|BV5
25W SSPA – Item D=BV1|BV2|BV3|BV4|BV5|BV6|BV7|BV8|BV9

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments for
Command or
Response to
Query

Description of arguments
(note that all arguments are ASCII numeric codes, that is,
ASCII codes between 48 and 57)

Response to Command (target to
controller)

Query
(Instruction
Code and
qualifier)

Up Converter
Stored Faults

n.a.

6 bytes

Query only.
>add/USF=ABCDEF’cr’’lf’ or
>add/USF=NO_FAULT’cr’’lf’

Where: A=Overtemperature Status, 0=OK, 1=FLT

B=S-Band Synthesizer Lock Status, 0=OK, 1=FLT
C=Ku-Band Synthesizer Lock Status, 0=OK, 1=FLT
D=Latched S-Band Synthesizer Lock Status,
0=OK, 1=FLT
E=Latched Ku-Band Synthesizer Lock Status, 0=OK,

1=FLT

F=Interprocessor comm.Status, 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)

USF= (message ok)
USF? (received ok, but invalid arguments
found)
USF* (message ok, but not permitted in
current mode)

USF?

Down Converter
Stored Faults

n.a.

6 bytes

Query only.
>add/DSF=ABCDEF’cr’’lf’ or
>add/DSF=NO_FAULT’cr’’lf’


Where: A=Overtemperature Status, 0=OK, 1=FLT

B=L-Band Synthesizer Lock Status,

0=OK, 1=FLT

C=Ku-Band Synthesizer Lock Status,

DSF= (message ok)
DSF? (received ok, but invalid arguments
found)
DSF* (message ok, but not permitted in
current mode)

DSF?