FSK Remote Control Commands
MN/KST2000AB.IOM
E-9
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(note that all arguments are ASCII numeric codes, that is, ASCII
codes between 48 and 57)
Response to Command (target to
controller)
Query
(Instruction
Code and
qualifier)
Where: x = 0 (Fault reporting disabled)
1 (Fault reporting enabled)
LFL* (message ok, but not permitted in
current mode)
Concise LNA
Settings
n.a.
2 bytes
Query only.
Where:
n = Power Enable; 0 (Off), 1(On)
x = Fault Enable; 0 (Disabled), 1 (Enabled)
CLS= (message ok)
CLS? (received ok, but invalid argument
found)
CLS* (message ok, but not permitted in
current mode)
CLS?
HPA Power
Enable
AMP=
1 byte
Command or Query.
Where: x=0(Off) or 1(On) Default is 1 (On)
Note: For EF Data SSPA only, which turns ON/OFF DC voltage
supplied to HPA.
AMP= (message ok)
AMP? (received ok,
but invalid arguments found)
AMP* (message ok, but not permitted in
current mode)
AMP?
HPA Fault
Enable
KFE=
1 byte
Command or Query.
Where: x=0 fault reporting disabled
y=1 fault reporting enabled
KFE= (message ok)
KFE? (received ok,
but invalid arguments found)
KFE* (message ok, but not permitted in
current mode)
KFE?