beautypg.com

Comtech EF Data KST-2000A/B User Manual

Page 168

background image

Ku-Band Satellite Transceiver

Revision 9

FSK Remote Control Commands

MN/KST2000AB.IOM

E-16

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments for
Command or
Response to
Query

Description of arguments
(note that all arguments are ASCII numeric codes, that is, ASCII
codes between 48 and 57)

Response to Command (target to
controller)

Query
(Instruction
Code and
qualifier)

Where: aaaaaaa=M&C ASSY # with dash and rev

bbbbbbb=Up converter ASSY # with dash and rev
ccccccc=Down Converter ASSY # with dash and rev
ddddddd=HPA firmware ASSY # with dash and rev

Firmware numbers have exceed 999-1X.

• Numbers 0000 to 6999 shall be decoded as 10000 to

16999.

Numbers 7000 to 9999 are decoded as is.

Serial Numbers

n.a.

36 bytes

Query only.
>add/SNM=aaaaaaaaabbbbbbbbcccccccccdddddddd’cr’’lf’

Where: aaaaaaaaa=M&C Serial Number

bbbbbbbb=Up Converter Serial Number
ccccccccc=Down Converter Serial Number
dddddddd=HPA firmware Serial Number

SNM= (message ok)
SNM? (received ok, but invalid arguments
found)
SNM* (message ok, but not permitted in
current mode)

SNM?

Summary
Fault
Status

n.a.

1 byte

Query only.
>add/SFS=x’cr’’lf’

Where: x=0=No Fault, 1=Fault

SFS= (message ok)
SFS? (received ok, but invalid arguments
found)
SFS* (message ok, but not permitted in
current mode)

SFS?

Concise Fault
Status

n.a.

7 bytes

Query only.
>add/CFS=ABCDEFG’cr’’lf’

Where: A=Common Equipment Status , 0=OK, 1=FLT

B=Reference Status, 0=OK, 1=FLT
C=AGS Status, 0=OK, 1=FLT
D=Up Converter Status, 0=OK, 1=FLT
E=Down Converter Status, 0=OK, 1=FLT
F=HPA Status, 0=OK, 1=FLT
G=LNA Status, 0=OK, 1=FLT

CFS= (message ok)
CFS? (received ok, but invalid arguments
found)
CFS* (message ok, but not permitted in
current mode)

CFS?