beautypg.com

Comtech EF Data KST-2000A/B User Manual

Page 170

background image

Ku-Band Satellite Transceiver

Revision 9

FSK Remote Control Commands

MN/KST2000AB.IOM

E-18

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments for
Command or
Response to
Query

Description of arguments
(note that all arguments are ASCII numeric codes, that is, ASCII
codes between 48 and 57)

Response to Command (target to
controller)

Query
(Instruction
Code and
qualifier)

Configuration
Lock

LOC=

1 byte

Command or Query
>add/LOC=’cr’’lf’
>add/LOC=x’cr’’lf’

Where: X = 0 (Unlock)
1 (Lock)

LOK= (message ok)
LOK? (received ok, but invalid
arguments found)
LOK* (message ok, but not permitted in
current mode)

LOC?

Concise Up
Converter Status

n.a.

4 bytes

Query only.
>add/CUS=ABCD’cr’’lf’

Where: A=Overtemperature Status, 0=OK, 1=FLT

B=L-Band Synthesizer Lock Status, 0=OK, 1=FLT
C=Ku-Band Synthesizer Lock Status, 0=OK, 1=FLT
D=Interprocessor Comm. Status, 0=OK, 1=FLT

CUS= (message ok)
CUS? (received ok, but invalid
arguments found)
CUS* (message ok, but not permitted in
current mode)

CUS?

Concise Down
Converter Status

n.a.

4 bytes

Query only.
>add/CDS=ABCD’cr’’lf’

Where: A=Overtemperature Status, 0=OK, 1=FLT

B=L-Band Synthesizer Lock Status, 0=OK, 1=FLT
C=Ku-Band Synthesizer Lock Status, 0=OK, 1=FLT
D=Interprocessor Comm. Status, 0=OK, 1=FLT

CDS= (message ok)
CDS? (received ok, but invalid
arguments found)
CDS* (message ok, but not permitted in
current mode)

CDS?

Concise HPA
Status

n.a.

5 bytes

Query only.
>add/CHS=ABCDE’cr’’lf’

Where: A=Overtemperature Status, 0=OK, 1=FLT, 2=NA

B=9.75V Status, 0=OK, 1=FLT, 2=NA
C=-5V Status, 0=OK, 1=FLT, 2=NA
D=BIAS Voltage Summary Status, 0=OK, 1=FLT, 2=NA
E=Interprocessor Comm. Status, 0=OK, 1=FLT, 2=NA


Note: Item D is the logical OR (shown as 1 or 0) of all the bias voltage
status information as shown:

CHS= (message ok)
CHS? (received ok, but invalid
arguments found)
CHS* (message ok, but not permitted in
current mode)

CHS?