2–14

2.4.2.3

16 Watt SSPA Connections

The 16 Watt SSPA input and output connections are shown in Figure 2-4

Figure 2-4. 16Watt SSPA

Note: When replacing fuses in the 16 Watt SSPA, use 6.3 amp, 3AG fuses, (2 each).



AC Line Input Connector (J3)








AC Power Connection

Pin

Function

Color

A Line

Brown

B Neutral Blue

C Ground Green/Yellow

Mating connection is molded power cord
Comtech PN

CA/84914-0223

Optional –48V DC DC Power

Connection

Pin

Function

A +

VDC

B Ground

C -

VDC

D No

Connect

Mating connector is a Comtech P/N
CN/STPG04F01(Amphenol PT06E-12-
4S(SR))

AC IN

GND

ERDE

J1

RF IN

J2

M/C