Chapter 3. OPERATION

This chapter provides the following information: Initial setup (single-thread system),
initial setup (redundant system), RJU-2000 Redundant Junction Unit description, 1:1 re-
dundant KST-2000A/B system operation, Up converter description, and Down converter
description.

3.1

Initial Setup (Single-Thread System)

This section details the procedures necessary to laboratory test a single-thread
KST-2000A/B system for the first time. Refer to Figure 3-1 for system setup.

Note: Ensure that the termination selected for the HPA output is sized to handle the

HPA output power.

1.

Apply power to the KST-2000A/B.

2.

After a few seconds ensure that the GREEN TX ON LED is flashing, and the
fault LED is extinguished. Refer to Section 4 if this is not the case.

3.

Using a KP-10 or PC equipped with a terminal or Windows

™ based M&C pro-

gram, ensure communication is available to the system M&C, via J2, remote
connector. (Refer to M&C software manual, P/N MN/M&CWIN.IOM)

Default Communication Parameters

Address

1

Baud

Rate

9600

Parity

Even

Stop

bits

2

Data length 7 bits