beautypg.com

Comtech EF Data KST-2000A/B User Manual

Page 40

background image

Ku-Band Satellite Transceiver

Revision 9

Installation

MN/KST2000AB.IOM

2–12

2.4.1.11

1:1 Connector (J10)

The 1:1 (J10) connector is a 32-pin circular, female connector used in redundant
applications for unit communications and switch control. Refer to Table 2-7 for pin
assignments.

Table 2-7. 1:1 Connector (J10) Pin Assignments

Pin

Signal

Description

A

UL_FLT_OUT

U/L Fault output – wires to adjacent unit UL_FLT_IN

B

DL_FLT_OUT

D/L Fault output – wires to adjacent unit DL_FLT_IN

C

TX_SW_CMD

Transmit switch command – momentary +28 VDC
output

D

RX_SW_CMD

Receive switch command – momentary +28 VDC output

E

IF_SW_CMD

IF switch command – momentary +28 VDC output

F

UL_OL_IND

U/L online indicator – wires to adjacent unit UL_OL_IN

G

DL_OL_IND

D/L online indicator – wires to adjacent unit DL_OL_IN

H

ENA_OUT

Redundancy enable – wires to adjacent unit ENA_IN

J

MODE_1_OUT

Mode output – wires to adjacent unit MODE_1_IN

K

MODE_2_OUT

Mode output – wires to adjacent unit MODE_2_IN

L

MODE_2_IN

Mode input – wires to adjacent unit MODE_2_OUT

M

MODE_1_IN

Mode input – wires to adjacent unit MODE_1_OUT

N

DL_OL_IN

D/L online – wires to adjacent unit DL_OL_IND

P

UL_OL_IN

U/L online input – wires to adjacent unit UL_OL_IND

R

DL_FLT_IN

D/L fault input – wires to adjacent unit DL_FLT_OUT

S

UL_FLT_IN

U/L fault input – wires to adjacent unit UL_FLT_OUT

T CONTINUITY

Continuity

detection

– wires to adjacent unit CONT RTN

U

A/B_UNIT

Unit designator GND = A unit, open = B unit

V

ENA_IN

Enable input – wires to adjacent unit ENA_OUT

W

IF_IND_B

IF switch, position B indicator input

X

IF_IND_A

IF switch, position A indicator input

Y

RX_IND_B

RX switch, position B indicator input

Z

RX_IND_A

RX switch, position A indicator input

a

TX_IND_B

TX switch, position B indicator input

b

TX_IND_A

TX switch, position A indicator input

c

IF_IND_COM

IF switch indicator common

d

RX_IND_COM

RX switch indicator common

e

TX_IND_COM

TX switch indicator common

f

IF_CMD_COM

IF switch command common

g RX_CMD_CO

M

RX switch command common

h

TX_CMD_COM TX switch command common

j

CONT_RTN

Continuity return – wires to adjacent unit continuity