Comtech EF Data KST-2000A/B User Manual
Page 40
Ku-Band Satellite Transceiver
Revision 9
Installation
MN/KST2000AB.IOM
2–12
2.4.1.11
1:1 Connector (J10)
The 1:1 (J10) connector is a 32-pin circular, female connector used in redundant
applications for unit communications and switch control. Refer to Table 2-7 for pin
assignments.
Table 2-7. 1:1 Connector (J10) Pin Assignments
Pin
Signal
Description
A
UL_FLT_OUT
U/L Fault output – wires to adjacent unit UL_FLT_IN
B
DL_FLT_OUT
D/L Fault output – wires to adjacent unit DL_FLT_IN
C
TX_SW_CMD
Transmit switch command – momentary +28 VDC
output
D
RX_SW_CMD
Receive switch command – momentary +28 VDC output
E
IF_SW_CMD
IF switch command – momentary +28 VDC output
F
UL_OL_IND
U/L online indicator – wires to adjacent unit UL_OL_IN
G
DL_OL_IND
D/L online indicator – wires to adjacent unit DL_OL_IN
H
ENA_OUT
Redundancy enable – wires to adjacent unit ENA_IN
J
MODE_1_OUT
Mode output – wires to adjacent unit MODE_1_IN
K
MODE_2_OUT
Mode output – wires to adjacent unit MODE_2_IN
L
MODE_2_IN
Mode input – wires to adjacent unit MODE_2_OUT
M
MODE_1_IN
Mode input – wires to adjacent unit MODE_1_OUT
N
DL_OL_IN
D/L online – wires to adjacent unit DL_OL_IND
P
UL_OL_IN
U/L online input – wires to adjacent unit UL_OL_IND
R
DL_FLT_IN
D/L fault input – wires to adjacent unit DL_FLT_OUT
S
UL_FLT_IN
U/L fault input – wires to adjacent unit UL_FLT_OUT
T CONTINUITY
Continuity
detection
– wires to adjacent unit CONT RTN
U
A/B_UNIT
Unit designator GND = A unit, open = B unit
V
ENA_IN
Enable input – wires to adjacent unit ENA_OUT
W
IF_IND_B
IF switch, position B indicator input
X
IF_IND_A
IF switch, position A indicator input
Y
RX_IND_B
RX switch, position B indicator input
Z
RX_IND_A
RX switch, position A indicator input
a
TX_IND_B
TX switch, position B indicator input
b
TX_IND_A
TX switch, position A indicator input
c
IF_IND_COM
IF switch indicator common
d
RX_IND_COM
RX switch indicator common
e
TX_IND_COM
TX switch indicator common
f
IF_CMD_COM
IF switch command common
g RX_CMD_CO
M
RX switch command common
h
TX_CMD_COM TX switch command common
j
CONT_RTN
Continuity return – wires to adjacent unit continuity