beautypg.com

Comtech EF Data KST-2000A/B User Manual

Page 164

background image

Ku-Band Satellite Transceiver

Revision 9

FSK Remote Control Commands

MN/KST2000AB.IOM

E-12



Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments for
Command or
Response to
Query

Description of arguments
(note that all arguments are ASCII numeric codes, that is,
ASCII codes between 48 and 57)

Response to Command (target to controller)

Query
(Instruction
Code and
qualifier)

Query Serial
Number DC

n.a.

9 bytes

Query only.
>add/SND=xxxxxxxxx’cr’’lf’

Where: xxxxxxxxx = 000000000 to 999999999

SND= (message ok)
SND? (received ok, but invalid arguments found)
SND* (message ok, but not permitted in current
mode)

SND?

Up Slice
Information
String

n.a.

41 bytes

Query only.
>add/UIF=fffff,bbbb,iii,aa,llll,gg,s,pp,rr,www,cc,’cr’lf’



Where: fffff=Start freq in MHz

bbbb= Freq range in MHz (bandwidth)
iii=IF freq in MHz
aa=max attenuation
llll= IFLO
gg= Cal GAIN in dB
s= 0 for Lowside LO, 1 for Highside LO
pp=rated output power in dBm
rr=max expected Raw Gain in dB
www=Channel bandwidth in MHz
cc=Allowed user atten range in dB



Ex: UIF=10950,1800,070,25,1180,45,1,10,57,036,25,

UIF= (message ok)
UIF? (received ok, but invalid argument found)
UIF* (message ok, but not permitted in current
mode)

UIF?