beautypg.com

Comtech EF Data KST-2000A/B User Manual

Page 54

background image

Ku-Band Satellite Transceiver

Revision 9

Operation

MN/KST2000AB.IOM

3–6

Step

Procedure

Remarks

8

Use the RFMC program a KP-10, or terminal
emulator, access unit A, enable backup operation in
manual mode using the remote commands listed in
Appendix B.6.

9

1. Using the backup manual operation command to

Unit A, place Unit A uplink and downlink online.

2. Ensure unit A reports that both its uplink and

downlink are on-line.

See Appendix B.6.

10

Perform the uplink setup steps listed in Section 3.1.1

Perform the downlink setup steps listed in Sec-
tion 3.1.2

11

1. Using the backup manual operation command to

Unit B, place Unit B uplink and downlink online.

2. Ensure that unit B reports its uplink and downlink

are both online.

See Appendix B.6.

12

Repeat step 14 for Unit B uplink.

Repeat step 14 for Unit B downlink.

13

Turn the RF output of the up converters of Unit A and
B On.

See Appendix B.3.

14

Execute a Reset Redundancy Fault command, to
Units A and B.

See Appendix B.9.

15

1. At this point there should not be any existing

faults.

2. Execute

a

command to

clear the fault logs of Unit A and Unit B, wait a
few moments.

3. Execute

a

command to

Units A and B, and a common equipment stored
faults command to verify.

See Appendix B.9.

16

Remove AC power from Units A and B, remove the
70 MHz (140MHz) test source from RJU-2000 J12,
the RX signal source, and coupler/attenuator from the
TX switch.

17

1. The system is ready for final installation to the

antenna feed.

2. Perform the rest of the system alignment to

applicable international, national, or local stan-
dards.

Note: If the KP-10 is used to communicate with the RJU-2000, the user must manually enter the
transceiver address. Using the global address will create anomalies.